grant

Heterogeneity of protein corona (PC) composition using highly sensitive magnetic levitation (MagLev) system

Organization UNIVERSITY OF COLORADOLocation COLORADO SPRINGS, UNITED STATESPosted 1 May 2024Deadline 31 Jul 2026
NIHUS FederalResearch GrantFY2025AdsorptionArtifactsBiochemistryBiodistributionBiologic CharacteristicBiologicalBiological CharacteristicsBiological ChemistryBiophysicsBloodBlood PlasmaBlood Reticuloendothelial SystemBlood SerumCommunicationComplexCore FacilityDataDevelopmentDevicesDiagnosticEquilibriumEvolutionExposure toFailureGoalsHeightHeterogeneityHumanKnowledgeLiquid substanceLiteratureMagnetismMasksMass Photometry/Spectrum AnalysisMass SpectrometryMass SpectroscopyMass SpectrumMass Spectrum AnalysesMass Spectrum AnalysisMeasurementMethodsMinorModelingModern ManMorphologic artifactsNatureNylonsOutcomePhysiologyPlasmaPlasma SerumPolyamidesPopulationPredictive FactorPreparationProceduresProcessPropertyProtein AnalysisProteinsProteomicsPublicationsResearchResolutionReticuloendothelial System, Serum, PlasmaRotationSafetyScientific PublicationSerumStructureSurfaceSystemTechniquesTreatment EfficacyVariantVariationanalytical toolbalancebalance functionbiologicbiophysical foundationbiophysical principlesbiophysical sciencesclinical translationclinically translatabledensitydevelopmentalfluidin vivointervention efficacyliquidliquid chromatography mass spectroscopymagneticnano medicinalnano medicinenano particlenano-sized particlenanomaterialsnanomedicinalnanomedicinenanoparticlenanoparticle therapynanosized particleparticleportabilitypreparationsprototyperesolutionsrhosuccesstherapeutic efficacytherapeutic nanoparticlestherapy efficacytool
Sign up free to applyApply link · pipeline · email alerts
— or —

Get email alerts for similar roles

Weekly digest · no password needed · unsubscribe any time

Full Description

ABSTRACT
The evolution of PC (layer of proteins/biomolecules that adsorbs at the surface of NPs upon contact by

biological fluids) in vivo still remains highly challenging due to the complexity of human physiology, the complex

nature of the biomolecules adsorbs on the surface, which is one of the main barriers of clinical translation of

nanomaterials. The ex vivo approaches for preparation of PC on the surface of the model NPs do not provide

homogenous corona formation as commonly perceived in the literature and the composition of the PC varies

even across identical NPs with the same sizes in the same batch and using the same biological fluid. The current

available PC characterizations or isolation techniques are not able to detect small variations in the composition

of the PC and heterogeneity of the PC structure. Therefore, non-specific extraction and pool analysis of the PC

in ex vivo condition may cause error and/or misinterpretation of the PC outcomes which significantly influence

the clinical translation of NPs. We show in the preliminary data that although the standard MagLev systems are

able to separate PC coated and uncoated NPs however, it is not able to discriminate among PC coated NPs

with various PC composition at the surface of the NPs due their very similar density and low resolution of the

standard MagLev systems. In this exploratory research we aim to develop a higher sensitivity MagLev system

to show the heterogeneity and variation of PC composition on the surface of the NPs, a critical ignored factor in

clinical translation of nanomaterials and failures of nanomedicine. In such highly sensitive MagLev configuration,

the resolution enhances 1 to 3 orders of magnitude (compared with sensitivity of standard MagLev system (i.e.,

10-3 g/cm3)) which is high enough to separate PC coated NPs with different PC coverages/compositions (e.g.,

number and type of the proteins at the surface) and very slight differences in the density (ranging from 0.001

g/cm3 to 0.00001 g/cm3 which is not detectable using standard MagLev system). Our preliminary data using a

prototype high sensitivity MagLev system as proof-of-concept, confirms that how identical objects (i.e.,

commercial identical nylon particles) with the same density and levitation heights in the standard MagLev system

have significant different levitation heights in a high sensitivity (prototype) MagLev system indicating low

resolution of the standard of the MagLev systems to detect such small variations/changes. The current state-of-

the-art in this type of separation is that there are simple proofs-of-concept of many of its foundational concepts,

but little use of fully developed methods by biologists and clinicians. This project will both solidify the fundamental

biophysical science of MagLev as a simple analytical tool in biochemistry and provide demonstrations of uses

for nanomedicine applications.

Grant Number: 5R03EB034817-03
NIH Institute/Center: NIH

Principal Investigator: Aliakbar Ashkarran

Sign up free to get the apply link, save to pipeline, and set email alerts.

Sign up free →

Agency Plan

7-day free trial

Unlock procurement & grants

Upgrade to access active tenders from World Bank, UNDP, ADB and more — with email alerts and pipeline tracking.

$29.99 / month

  • 🔔Email alerts for new matching tenders
  • 🗂️Track tenders in your pipeline
  • 💰Filter by contract value
  • 📥Export results to CSV
  • 📌Save searches with one click
Start 7-day free trial →